CRYSTAL QUEST®  4000 GPD Reverse Osmosis System

Detailed Description

 

System Specifications

Design

Vertical

Gallons Per Day

4000 @ 77 F

Dimensions (Approx.)

19" x 23" x 46"

Weight (Approx.)

235 lbs.

Concentrate Re-Circulate

Optional

Auto Flush

Optional

Element Size (in.)

4040 TFC HF1

Elements (Qty.)

2

Motor HP

1

Voltage

110 or 220 Volts AC

Hertz

60 or 50 cycle

Feed Connection

3/4"

Product Connection

1"

Waste Connection

1"

 

Operating Specifications

Minimum Feed Pressure

35 psi

Minimum NaCl - % Rejection

96%

Minimum Feed (GPM)

6

Maximum Hardness

15 Grains / Gallon

Maximum TDS

2000 ppm

Operating Pressure

150 psi

Maximum NaCl - % Rejection

98.5%

Maximum Feed (GPM)

15

pH Range

3 - 11

Maximum Temperature

1050 F

 
 

Membrane: Two 2" x 40" TFC HF1 Membranes, For maximum rejection of impurities and high flow.

Membrane Housing: Two 2.5" x 40" Champ Membrane Housing, Features a patented design and requires no tools for servicing.

Pump & Motor: One Goulds 1 HP Multistage Pump and Motor, 110 or 220 volts AC, 60 or 50 hertz, single phase, Designed for continuous high pressures.

Frame: Aluminum, White Powder Coated, Corrosion resistant, and light weight.

Sediment Filter: One 4.5" x 20" Big White 5 Micron Sediment Filter, Removes sediments and protects the system.

Carbon Block: One 4.5" x 20" Big White 10 Micron Carbon Block, Removes chlorine, odor, and taste from incoming feed water.

Sediment Filter: One 4.5" x 20" Big White 1 Micron Sediment Filter, Removes sediments and protects the system down to 1 micron.

Filter Housing: three 4.5" x 20" Big Grey Double O-Ring Filter Housings, Offers durability and improved sealing capabilities.

Pressure Gauges: Two 2.5" Gauges, 0-300 PSI, Panel Mount, Glycerin Filled,  and Two 1.5" Gauges, 0-160 PSI, Top Mount Dry Gauges, For monitoring the system's operating pressure, the filter and carbon operating pressure.

Low Pressure Switch: One McCann's Low Pressure Switch, Safety device to protect the pump from running dry when there is insufficient feed water pressure.

Solenoid Valve: One Solenoid Valve with Manual Override, 110 or 220 Volts AC, 60 or 50 hertz, Assists with the on/off functionality of the system.

Manual Flush Valve: One 1/2" Brass Needle Valve, Regulates the product to waste ratio (systems recovery).

Switch: One Manual On/Off Switch.

Computer Controller: One Minitrol Computer Controller, 110 or 220 volts AC, with pre-treat lockout, tank full contacts, low pressure monitoring, and alarm.

Flow Meters: One Product (0-10 GPM) & One Waste (0-10 GPM) Flow Meters, Enables operator to accurately adjust product to waste ratio, and monitor systems performance.

TDS Meter: One Panel Mount TDS Meter, Provides accurate readings of the feed and product water quality.

Easy Maintenance & Operation: CRYSTAL QUEST® commercial reverse osmosis systems feature a compact design and have all of their components strategically located for easy access and inspection

Optional Features

 .

Stainless Steel Housings: Two 4” x 40” Puro Tech Stainless Steel Membrane Housings, 1/2” FNPT.
 
High Pressure Switch: One Square D High Pressure Switch, Automatically starts when the tank pressure falls below 40 psi, and stops when the pressure reaches 60 psi.
 
Auto Flush: This feature will flush the system's membranes with the feed water, thus extending membrane life.
 
Float Switch: One Mechanical Float Switch, For atmospheric storage tank applications.
 
Concentrate Re-Circulate: This feature offers a higher recovery rate for the system by taking a percentage of the waste water and feeding it back into the system

 

 
  • Additional cost will apply to listed price for custom modification based on water laboratory test report.
 

Policies | Copyright | Legal CRYSTAL QUEST®